 The least-common form of echo-based level measurement is laser, which uses pulses of laser light reflected off the surface of a liquid to detect the liquid level. Perhaps the most limiting factor with laser measurement is the necessity of having a sufficiently reflective surface for the laser light to “echo” off of. Many liquids are not reflective enough for this to be a practical measurement technique, and the presence of dust or thick vapors in the space between the laser and the liquid will disperse the light, weakening the light signal and making the level more difficult to detect. However, lasers have been applied with great success in measuring distances between objects.

Laser Level Measurement Principle :

Laser transmitters used for level measurement basically work upon the same operating principle as ultrasonic level sensors. The only difference between two methods is that the former employs speed of light whereas the latter makes use of sound waves speed. Laser level measurement devices can work with variety of materials such as bulk solids, slurries, and opaque fluids like dirty sumps, milk, and liquid styrene etc. Just like an ultrasonic sensor, a laser transmitter is also mounted at the top of the tank which then directs a short pulse of light in downward direction towards the surface of the process liquid. This light is then reflected back to the sensor. The measurement system includes a timing circuit which is used to determine the time taken by the light signal to return back and hence finds out the distance between the sensor and the process material. A figure depicting the working of a typical laser level transmitter is shown in the figure below.

Image Credits : Chipkin Automation System

Advantages of laser level measurement :
  • “Lasers have virtually no beam spread (0.2° beam divergence) and no false echoes, and can be directed through spaces as small as 2 in.
  • Laser transmitters are capable of providing accurate results, even in processes involving heavy vapors and foam.
  • They can be conveniently used with vessels having multiple blockades. Moreover, these devices can work with distances as high as 1500 ft.
  • “For high-temperature or high-pressure applications such as in reactor vessels, lasers must be used in conjunction with specialized sight windows to isolate the transmitter from the process. These glass windows must pass the laser beam with minimal diffusion and attenuation and must contain the process conditions.”
  • As compared to ultrasonic and microwave waves, the wavelength of light waves is very short, due to which they experience no virtual beam divergence, hence a laser beam can be targeted on a point without facing any intervention from the nearby entities.
  • “The laser radiation propagates through the medium at the speed of light. This means that very high update rates are achievable, with none of the ‘lock-in’ problems that can be experienced when using ultrasonic instruments.”
  • Laser level measurement is absolutely independent of the pressure or temperature variations of the medium such as air. Consequently, the speed of light passing via any gaseous medium does not vary at all. Even in level measurement applications involving unidentified and frequently varying gaseous densities such as petrol or gas tanks, laser level transmitters offer accurate results with no calibration issues.
  • In comparison to other level measurement techniques like ultrasonic, radar, nuclear or mechanical methods, laser technique is considered to be highly developed in technology.
  • Laser level transmitters provide very quick and accurate response than other techniques. Besides, they are simpler to apply.
  • Unlike radar level and ultrasonic level technology, the performance of laser level transmitters is remains unaffected by the dielectric constant of the process material or propagation velocity in the vapor space respectively.
  • The laser beam transmitted by the sensor doesn’t undergo much divergence hence it can aim and sense smaller areas as compared to than radar and ultrasonic level measurement devices.
  • Furthermore, laser level transmitters can be applied in areas where other level measurement technologies fail to work, for example, inside the chute of a bin.
  • Disadvantages of laser level transmitters :

  • Use of laser level measurement techniques prove to be very expensive.
  • The strength of the laser beam transferred between the laser level transmitter and process material may sometimes get degraded due to which the functioning of the level detection system can suffer. This degradation can happen at any of the three stages: at the sensor/detector, in transit between the sensor and the process material, or at the surface of the process material.
  • Presence of dirt, dust or any other type of coating on a laser level transmitter can seriously affect the performance of these devices since it weakens the strength of the laser signal. Hence, routine maintenance must be carried out carefully for preventing accumulations and coatings over time and proper functioning of laser level measurement devices. For some applications, these sensors can be enclosed inside a tube or cleaned with gas to keep them in a working condition.
  • Besides, their accuracy can also get affected depending upon the surface of the process material which reflects back the laser beam to the sensor. “For example, the laser beam will likely measure the top of a layer of foam by reflecting off the top of the foam. If the foam is transparent to the laser energy, the beam may reflect from the foam/liquid interface and measure the liquid level. Translucent foam might cause the level measurement to represent a location within the foam.
  • Foam conditions usually changes with time and results in inconsistent level measurement readings.


Comments

Popular posts from this blog

PLC Program for Mixing Tank

 Create a ladder diagram for controlling a batch mixing process. Implement a PLC program for mixing tank or Mixing Process using PLC Ladder Logic. PLC Program for Mixing Tank Fig : Mixing tank A tank is used to mix two liquids. The required control circuit operates as follows: A. When the START button is pressed, solenoids A and B energize. This permits the two liquids to begin filling the tank. B. When the tank is filled, the float switch trips. This de-energizes solenoids A and B and starts the motor used to mix the liquids together. C. The motor is permitted to run for 1 minute. After 1 minute has elapsed, the motor turns off and solenoid C energizes to drain the tank. D. When the tank is empty, the float switch de- energizes solenoid C. E. A STOP button can be used to stop the process at any point. F. If the motor becomes overloaded, the action of the entire circuit will stop. G. Once the circuit has been energized, it will continue to operate until it is manually stopped. Solution : A

What is Relay? How it Works? Types, Applications, Testing

 We use relays for a wide range of applications such as home automation, cars and bikes (automobiles), industrial applications, DIY Projects, test and measurement equipment, and many more. But what is Relay? How a Relay Works? What are the Applications of Relays? Let us explore more about relays in this guide. What is a Relay? A Relay is a simple electromechanical switch. While we use normal switches to close or open a circuit manually, a Relay is also a switch that connects or disconnects two circuits. But instead of a manual operation, a relay uses an electrical signal to control an electromagnet, which in turn connects or disconnects another circuit. Relays can be of different types like electromechanical, solid state. Electromechanical relays are frequently used. Let us see the internal parts of this relay before knowing about it working. Although many different types of relay were present, their working is same. Every electromechanical relay consists of an consists of an Electroma

Chlorine dioxide Analyzer Principle

 Chlorine dioxide measurement Chlorine dioxide (ClO2) is an instable, non-storable, toxic gas with a characteristic scent. The molecule consists of one chlorine atom and two oxygen atoms – represented in the chemical formula ClO2. It is very reactive. To avoid the risk of spontaneous explosions of gaseous chlorine dioxide or concentrated solutions, it is generally handled in dilution with low concentrations. ClO2 is soluble in water, but tends to evaporate quickly. Typically it is prepared on site, for example from hydrochloric acid and sodium chlorite. The procedure provides solutions with approx. 2 g/l ClO2 that can be safely handled and stored for several days. Image Credits : krohne Sensor Parts : Reference electrode Applied chlorine dioxide specific potential Current needed to maintain the constant potential Counter electrode Measuring electrode The disinfection effect of ClO2 is due to the transfer of oxygen instead of chlorine, so that no chlorinated byproducts are formed. ClO2