Skip to main content

What is Integral Flow Orifice Assembly?

 Integral Flow Orifice Assembly is used when Differential Pressure Transmitter has to be directly mounted on the orifice assembly. This eliminates the cost of installation of Differential Pressure Transmitter with impulse piping up to the orifice assembly.

Integral Flow Orifice Assembly


The transmitter is mounted on the orifice assembly through a 3/5 Valve H-type manifold. Available with line sizes of 2″ & below. However, due to the process temperature limits of the transmitter, this assembly cannot be used tor process temperatures above 120 degrees Centigrade.

The assembly consists of an orifice plate between two integral blocks having corner taps. Generally, a meter run pipe is recommended with the upstream length of 750mm and downstream length 0‘ 250mm. The pipes are welded to the blocks with end flanges.

Advantages of Integral Meter run assembly:
The use of an integral orifice flow meter will eliminate the three measurement inaccuracies recorded in small orifice line installations.

The Integral Orifice honed body reduces ID uncertainty.

By inserting precision bored upstream and downstream sections of pipe, the velocity profile distortion due to pipe roughness is reduced.

The self-centering design of the Integral Orifice Plate eliminates plate misalignment.
Improves Reliability and Maintenance Costs
The integral orifice flow meter eliminates impulse lines, reducing leak points by over 50% and decrease start-up time due to the flexibility of numerous process connection options. The direct mount design minimizes line plugging by eliminating long lines, small-bore ports, and services while providing consistently reliable installations.

*Accuracy up to ±0.5% of the volumetric flow rate.
*The integral manifold head allows direct mounting of DP transmitters.
*Ideal fluid types: liquid, gas, and steam
Integral Orifice Assembly with flange union, manifold valve, DP transmitter & end flanges
Meter runs are supplied as a complete unit of normally 1M length to ensure the necessary straight pipe length to achieve the highest possible efficiency.

These are available with line sizes mostly below 50mm with a corner tap.

These are used for the measurement of small flow rates precisely where high accuracy of flow rates is required.

Types of Meter Runs:
1.Orifice Flange union with Meter -run.
2.Orifice flange union with Carrier ring & Meter –run.
End Connection: Socket Weld, Screwed and Flanged ends with meter run piping suitable to ANSI, IS & DIN flanges.


Comments

  1. Thanks for such a pleasant post. This post loaded with lots of useful information. Keep it up. If you are looking for the best information and suggestions related to Stainless Steel Pipe manufacturers in India then visit Great steel & metals.


    ReplyDelete
  2. Thanks for shared that blog with us. If anyone here searching ss fasteners manufacturers in india then visit VIHA STEEL & FORGING.

    ReplyDelete
  3. Hi there to everyone, the contents present at this web page are actually amazing for people knowledge, well, you can also visit 316l stainless steel tube suppliers for more Oshwin Overseas related information and knowledge. Keep up the good work.

    ReplyDelete
  4. Really helpful down to the ground, happy to read such a useful post. I got a lot of information through it and I will surely keep it in my mind. Keep sharing. If you are looking for some useful data and information regarding 321 Stainless Steel Sheet then visit Great steel & metals.

    ReplyDelete
  5. Your blog is awfully appealing. I am contented with your post. I regularly read your blog and its very helpful. If you are looking for the best duplex stainless steel tube manufacturers, then visit Perfect Impex. Thanks! I enjoyed this blog post.

    ReplyDelete
  6. After going through your contents I realize that this is the best of my knowledge as it provides the best information and suggestions. This is very helpful and share worthy. If you are looking for the best ss fasteners manufacturers in india then visit nickelalloysonline. Keep sharing more.


    ReplyDelete

Post a Comment

Popular posts from this blog

PLC Program for Mixing Tank

 Create a ladder diagram for controlling a batch mixing process. Implement a PLC program for mixing tank or Mixing Process using PLC Ladder Logic. PLC Program for Mixing Tank Fig : Mixing tank A tank is used to mix two liquids. The required control circuit operates as follows: A. When the START button is pressed, solenoids A and B energize. This permits the two liquids to begin filling the tank. B. When the tank is filled, the float switch trips. This de-energizes solenoids A and B and starts the motor used to mix the liquids together. C. The motor is permitted to run for 1 minute. After 1 minute has elapsed, the motor turns off and solenoid C energizes to drain the tank. D. When the tank is empty, the float switch de- energizes solenoid C. E. A STOP button can be used to stop the process at any point. F. If the motor becomes overloaded, the action of the entire circuit will stop. G. Once the circuit has been energized, it will continue to operate until it is manually stopped. Solution...

What is Relay? How it Works? Types, Applications, Testing

 We use relays for a wide range of applications such as home automation, cars and bikes (automobiles), industrial applications, DIY Projects, test and measurement equipment, and many more. But what is Relay? How a Relay Works? What are the Applications of Relays? Let us explore more about relays in this guide. What is a Relay? A Relay is a simple electromechanical switch. While we use normal switches to close or open a circuit manually, a Relay is also a switch that connects or disconnects two circuits. But instead of a manual operation, a relay uses an electrical signal to control an electromagnet, which in turn connects or disconnects another circuit. Relays can be of different types like electromechanical, solid state. Electromechanical relays are frequently used. Let us see the internal parts of this relay before knowing about it working. Although many different types of relay were present, their working is same. Every electromechanical relay consists of an consists of an Elect...

Chlorine dioxide Analyzer Principle

 Chlorine dioxide measurement Chlorine dioxide (ClO2) is an instable, non-storable, toxic gas with a characteristic scent. The molecule consists of one chlorine atom and two oxygen atoms – represented in the chemical formula ClO2. It is very reactive. To avoid the risk of spontaneous explosions of gaseous chlorine dioxide or concentrated solutions, it is generally handled in dilution with low concentrations. ClO2 is soluble in water, but tends to evaporate quickly. Typically it is prepared on site, for example from hydrochloric acid and sodium chlorite. The procedure provides solutions with approx. 2 g/l ClO2 that can be safely handled and stored for several days. Image Credits : krohne Sensor Parts : Reference electrode Applied chlorine dioxide specific potential Current needed to maintain the constant potential Counter electrode Measuring electrode The disinfection effect of ClO2 is due to the transfer of oxygen instead of chlorine, so that no chlorinated byproducts are formed. C...