V Cone Flow Meter Working Principle

 The V-Cone flow meter like several other popular meters is a differential pressure (or “DP”) meter. These meters all work according to the same principle of DP flow devices.

That is an obstruction in the pipe (i.e., a reduction in the cross sectional area available to the flow) causes an increase in flow velocity and a corresponding reduction in pressure.

Hence be measuring the upstream pressure, the temperature and the difference in the static pressure between the upstream and the minimum cross sectional areas the flow rate can be determined as long as the fluid properties are known. The flow rate determination is done by applying the laws of conservation of mass and energy.

However, there are important differences between the V-Cone meter design and other DP meter types. These differences give the V-Cone meter important performance advantages.

These advantages include the ability of the V-Cone meter to operate with very short upstream and downstream straight pipe lengths, to create a low total pressure (or “head loss”), to create a very stable DP, to give a large turn down, to create relatively low signal noise and to cope well with liquid and particulates in the gas stream.

V Cone Flow Meter

Cone meters (e.g. V-cones) are proprietary meters and are essentially an inverted Venturi tube. Instead of a contraction in the pipe, the fluid flows around a central cone as shown in the following diagram.

Cone meters have proved popular as it is claimed they require very little upstream straight pipework before the meter to provide accurate measurements. This benefit is due to the fluid flowing around the cone which is described as “conditioning” the flow.

One of the downsides of cone meters is the lack of standards governing this type of meter, as they have been a proprietary device, and there has been a lack of independent data available to provide confidence in claimed performance.

Unlike Venturi tubes, orifice plates and nozzles, which are manufactured to tolerances specified in ISO 5167, cone meters are not manufactured to a specified tolerance and must be individually calibrated before use.

Principle of Operation
The V-Cone flow meter is a differential pressure type flow meter. Basic theories behind differential pressure type flow meters have existed for over a century.

The principal theory among these is Bernoulli’s theorem for the conservation of energy in a closed pipe. This states that for a constant flow, the pressure in a pipe is inversely proportional to the square of the velocity in the pipe.

Simply, the pressure decreases as the velocity increases. For instance, as the fluid approaches the V-Cone flow meter, it will have a pressure of P1 .
As the fluid velocity increases at the constricted area of the V-Cone, the pressure drops to P2 , as shown in Figure 1. Both P1 and P2 are measured at the V-Cone flow meter’s taps using a variety of differential pressure transducers.

The DP created by a V-Cone flow meter will increase and decrease exponentially with the flow velocity. As the constriction takes up more of the pipe cross-sectional area, more differential pressure will be created at the same flow rates.

The beta ratio equals the flow area at the largest cross section of the cone (converted to an equivalent diameter) divided by the meter’s inside diameter

Advantages of V Cone Flow Meter :
*Lower sensitivity than orifice plates and Venturi tubes to installation effects
*Shorter installation lengths
*Less pressure loss than orifice plates
*Wafer (between flange) versions
*Effective for wet gas flow measurement applications

Disadvantages of V Cone Flow Meter :
*Lack of standards
*Not as much data available as “ISO 5167” meters
*Pressure loss higher than Venturi tubes





Comments

Popular posts from this blog

PLC Program for Mixing Tank

 Create a ladder diagram for controlling a batch mixing process. Implement a PLC program for mixing tank or Mixing Process using PLC Ladder Logic. PLC Program for Mixing Tank Fig : Mixing tank A tank is used to mix two liquids. The required control circuit operates as follows: A. When the START button is pressed, solenoids A and B energize. This permits the two liquids to begin filling the tank. B. When the tank is filled, the float switch trips. This de-energizes solenoids A and B and starts the motor used to mix the liquids together. C. The motor is permitted to run for 1 minute. After 1 minute has elapsed, the motor turns off and solenoid C energizes to drain the tank. D. When the tank is empty, the float switch de- energizes solenoid C. E. A STOP button can be used to stop the process at any point. F. If the motor becomes overloaded, the action of the entire circuit will stop. G. Once the circuit has been energized, it will continue to operate until it is manually stopped. Solution : A

What is Relay? How it Works? Types, Applications, Testing

 We use relays for a wide range of applications such as home automation, cars and bikes (automobiles), industrial applications, DIY Projects, test and measurement equipment, and many more. But what is Relay? How a Relay Works? What are the Applications of Relays? Let us explore more about relays in this guide. What is a Relay? A Relay is a simple electromechanical switch. While we use normal switches to close or open a circuit manually, a Relay is also a switch that connects or disconnects two circuits. But instead of a manual operation, a relay uses an electrical signal to control an electromagnet, which in turn connects or disconnects another circuit. Relays can be of different types like electromechanical, solid state. Electromechanical relays are frequently used. Let us see the internal parts of this relay before knowing about it working. Although many different types of relay were present, their working is same. Every electromechanical relay consists of an consists of an Electroma

Chlorine dioxide Analyzer Principle

 Chlorine dioxide measurement Chlorine dioxide (ClO2) is an instable, non-storable, toxic gas with a characteristic scent. The molecule consists of one chlorine atom and two oxygen atoms – represented in the chemical formula ClO2. It is very reactive. To avoid the risk of spontaneous explosions of gaseous chlorine dioxide or concentrated solutions, it is generally handled in dilution with low concentrations. ClO2 is soluble in water, but tends to evaporate quickly. Typically it is prepared on site, for example from hydrochloric acid and sodium chlorite. The procedure provides solutions with approx. 2 g/l ClO2 that can be safely handled and stored for several days. Image Credits : krohne Sensor Parts : Reference electrode Applied chlorine dioxide specific potential Current needed to maintain the constant potential Counter electrode Measuring electrode The disinfection effect of ClO2 is due to the transfer of oxygen instead of chlorine, so that no chlorinated byproducts are formed. ClO2