 Turbidity is an optical property of water based on the amount of light scattered and absorped by collodial and suspended particles. The turbidity value measured in FNU, FTU, NTU etc. is the quantitative statement of this qualitative phenomenon.

Nephelometry means that the light source and the photodetector are set at a 90-degree angle from each other. This is considered the angle most sensitive to light scatter regardless of particle size

The goal of measuring turbidity is to get an indication for the concentration of scattering particles in a medium. This can be done by determination of the light loss of the transmitted beam or the measurement of the light scattered sideways. Both methods deliver proportional data to particle concentration and are therefore suitable for measuring turbidity. They however differ in application and concentration levels. Scattered light measurement principle is more suitable for the detection of lower concentrations, while transmission (reflection or absorption) measurement is used for higher concentrations.

Image Credits : krohne

The device measures scatted light at 90° which is according to ISO 7027 / DIN EN 27027 to be used for turbidity values below 40 NTU.The NIR light source and receiver are positioned in a 90° angle to each other. The light transmitted from the source is directed in equal strength to the reference detector and into the medium. Light is scattered from the particles and the portion which is scattered at a 90° angle is received by the detector. The meter now compares the light from the reference detector and scattered light receiver and calculates the turbidity value.

The measurement unit for the turbidity measured at a 90° angle varies depending on country in and is according to ISO 7027 Formazine Nephelometric Unit (FNU), but the more commonly used terminology is Nephelometric Turbidity Unit (NTU) stated within the US EPA 180.1. Both units compare 1 to 1.

The advantage of the using NIR as light source as stated in the ISO 7027 is that this sensor is not affected by colour of the medium measured.

Source : krohne



Comments

Popular posts from this blog

PLC Program for Mixing Tank

 Create a ladder diagram for controlling a batch mixing process. Implement a PLC program for mixing tank or Mixing Process using PLC Ladder Logic. PLC Program for Mixing Tank Fig : Mixing tank A tank is used to mix two liquids. The required control circuit operates as follows: A. When the START button is pressed, solenoids A and B energize. This permits the two liquids to begin filling the tank. B. When the tank is filled, the float switch trips. This de-energizes solenoids A and B and starts the motor used to mix the liquids together. C. The motor is permitted to run for 1 minute. After 1 minute has elapsed, the motor turns off and solenoid C energizes to drain the tank. D. When the tank is empty, the float switch de- energizes solenoid C. E. A STOP button can be used to stop the process at any point. F. If the motor becomes overloaded, the action of the entire circuit will stop. G. Once the circuit has been energized, it will continue to operate until it is manually stopped. Solution : A

What is Relay? How it Works? Types, Applications, Testing

 We use relays for a wide range of applications such as home automation, cars and bikes (automobiles), industrial applications, DIY Projects, test and measurement equipment, and many more. But what is Relay? How a Relay Works? What are the Applications of Relays? Let us explore more about relays in this guide. What is a Relay? A Relay is a simple electromechanical switch. While we use normal switches to close or open a circuit manually, a Relay is also a switch that connects or disconnects two circuits. But instead of a manual operation, a relay uses an electrical signal to control an electromagnet, which in turn connects or disconnects another circuit. Relays can be of different types like electromechanical, solid state. Electromechanical relays are frequently used. Let us see the internal parts of this relay before knowing about it working. Although many different types of relay were present, their working is same. Every electromechanical relay consists of an consists of an Electroma

Chlorine dioxide Analyzer Principle

 Chlorine dioxide measurement Chlorine dioxide (ClO2) is an instable, non-storable, toxic gas with a characteristic scent. The molecule consists of one chlorine atom and two oxygen atoms – represented in the chemical formula ClO2. It is very reactive. To avoid the risk of spontaneous explosions of gaseous chlorine dioxide or concentrated solutions, it is generally handled in dilution with low concentrations. ClO2 is soluble in water, but tends to evaporate quickly. Typically it is prepared on site, for example from hydrochloric acid and sodium chlorite. The procedure provides solutions with approx. 2 g/l ClO2 that can be safely handled and stored for several days. Image Credits : krohne Sensor Parts : Reference electrode Applied chlorine dioxide specific potential Current needed to maintain the constant potential Counter electrode Measuring electrode The disinfection effect of ClO2 is due to the transfer of oxygen instead of chlorine, so that no chlorinated byproducts are formed. ClO2