Skip to main content

Swirl Flow Meters Working Principle

 Swirl flow meters combine the advantages of turbine and vortex flow meter technologies. They have a high turndown ratio and high accuracy (turbine). And they are highly reliable, robust and maintenance free (vortex)

Swirl Flow Meters

Swirl Flow meters Principle
A turbine-shaped inlet section forces the axial flow entering the flow meter into a rotational movement. A vortex core forms in the centre of the primary rotation. A secondary rotation forms in the vortex core producing thread-like spirals.

The frequency of this secondary rotation is linearly proportional to the flow rate over a wide Reynolds Number range. Pressure variations resulting from the secondary rotation are detected by a piezo sensor and converted into electrical pulses.

These pulses are processed in the DSP converter into scaled analog and digital signals which displays the measured flow value.

Why Swirl Flow Meter is Advantage ?
The swirl flow meter advances vortex flow technology by improving accuracy, simplifying installation, increasing turndown, and reducing cost of ownership.

Swirl meters operate on similar vortex flow meter principles, but have certain advantages.
1.Swirl meters create their own flow profile within the meter, so they require only three straight pipe diameters upstream and one downstream. Vortex meters typically require a minimum of 15 diameters upstream and five downstream to develop a proper flow profile for accurate measurements. So the swirl flow meter better fits applications with tight piping requirements.

2.When applying vortex meters, the user typically chooses a flow meter reduced by one or two pipe sizes from the process pipeline size. This ensures that the flow meter experiences the higher velocities required across the desired flow range, but adds piping reduction and expansion costs. Swirl meters require lower flow velocities for proper operation, and so usually may be sized the same as the process pipe size.

3.Swirl meters have a turndown ration of up to 30:1, while most vortex meters are limited to 20:1 turndown ratios. Additionally swirl meters can perform to viscosities of up to 30 cp while vortex meters are generally limited to 8-10 cp maximum.

4.Swirl meters offer a higher degree of accuracy, up to 0.5% better than most vortex meters in gas applications.

For these reasons, swirl flow meters have been gaining ground on vortex flow meters and are currently experiencing the growth.
The swirl meter operates under the same technology as the vortex flow meter. It takes advantage of vortex shedding principles that occur when a flowing fluid comes up against a bluff obstacle in its path. Additionally, the swirl meter adds a “twist” in conditioning the fluid, which results in the reduced installation considerations mentioned above, while improving performance.
The swirl meter forces incoming fluid through a fixed swirl inducing element located at the upstream inlet of the meter body. The “swirler” imparts a tangential velocity to the fluid, and then accelerates the flow via a reduction in the meter body bore.

The primary fluid rotation caused by the swirler has at its core a low-pressure zone. This low-pressure zone is thrown into a secondary rotation proportional to flow rate. The same piezoelectric sensor as used in vortex meters measures the frequency of this phenomenon at the point of maximum fluid velocity.

An increase in the meter’s bore as the fluid approaches the meter outlet decelerates the fluid to its original velocity. A “deswirler” welded to the meter body near the outlet eliminates the tangential velocity imparted to the fluid at the inlet. This avoids affecting operation of other downstream instrumentation.

Limitations
While both swirl and vortex shedders offer a wide measurement range, they cannot measure fluid flows down to a true zero. Some minimal fluid velocity must be present to act upon the piezoelectric sensing element.

So these meters may not register low levels of fluid movement in the pipeline. For this reason swirl and vortex meters are not readily suitable to batch processing with start and stop flow actions. In some cases continuous flow with a diverter can overcome this consideration

Both swirl and vortex meters are also susceptible to external interference such as pipe vibration, EMF, and hydraulic noise. Interference occurs if these disturbances are within the frequency range of the meter and of higher amplitude than the flow signal itself. The meter may confuse the disturbance with a flow signal, reporting a false flow rate.

The sophisticated digital signal processing can filter these conditions, but the best cure is to treat the root cause of the interference by removing the disturbing influence. So when such disturbances arise, users should check into piping vibration, anchoring, location, and proximity to electrical devices.

Typical Applications of Swirl and Vortex flow meters





Comments

Popular posts from this blog

PLC Program for Mixing Tank

 Create a ladder diagram for controlling a batch mixing process. Implement a PLC program for mixing tank or Mixing Process using PLC Ladder Logic. PLC Program for Mixing Tank Fig : Mixing tank A tank is used to mix two liquids. The required control circuit operates as follows: A. When the START button is pressed, solenoids A and B energize. This permits the two liquids to begin filling the tank. B. When the tank is filled, the float switch trips. This de-energizes solenoids A and B and starts the motor used to mix the liquids together. C. The motor is permitted to run for 1 minute. After 1 minute has elapsed, the motor turns off and solenoid C energizes to drain the tank. D. When the tank is empty, the float switch de- energizes solenoid C. E. A STOP button can be used to stop the process at any point. F. If the motor becomes overloaded, the action of the entire circuit will stop. G. Once the circuit has been energized, it will continue to operate until it is manually stopped. Solution...

What is Relay? How it Works? Types, Applications, Testing

 We use relays for a wide range of applications such as home automation, cars and bikes (automobiles), industrial applications, DIY Projects, test and measurement equipment, and many more. But what is Relay? How a Relay Works? What are the Applications of Relays? Let us explore more about relays in this guide. What is a Relay? A Relay is a simple electromechanical switch. While we use normal switches to close or open a circuit manually, a Relay is also a switch that connects or disconnects two circuits. But instead of a manual operation, a relay uses an electrical signal to control an electromagnet, which in turn connects or disconnects another circuit. Relays can be of different types like electromechanical, solid state. Electromechanical relays are frequently used. Let us see the internal parts of this relay before knowing about it working. Although many different types of relay were present, their working is same. Every electromechanical relay consists of an consists of an Elect...

Chlorine dioxide Analyzer Principle

 Chlorine dioxide measurement Chlorine dioxide (ClO2) is an instable, non-storable, toxic gas with a characteristic scent. The molecule consists of one chlorine atom and two oxygen atoms – represented in the chemical formula ClO2. It is very reactive. To avoid the risk of spontaneous explosions of gaseous chlorine dioxide or concentrated solutions, it is generally handled in dilution with low concentrations. ClO2 is soluble in water, but tends to evaporate quickly. Typically it is prepared on site, for example from hydrochloric acid and sodium chlorite. The procedure provides solutions with approx. 2 g/l ClO2 that can be safely handled and stored for several days. Image Credits : krohne Sensor Parts : Reference electrode Applied chlorine dioxide specific potential Current needed to maintain the constant potential Counter electrode Measuring electrode The disinfection effect of ClO2 is due to the transfer of oxygen instead of chlorine, so that no chlorinated byproducts are formed. C...