 Flow measurement has a history of about 3000 years. It has been studied only in the last 200 years and in the last 30 years all the new techniques have evolved. There is now a wide variety of methods available to measure the flow of liquids, solids, gases and vapours.

Flow measurement Basics

There are three different flow quantities to be measured :-

The actual velocity of the fluid at a given point (measured in metres per second).

The volume rate of flow (measured in metres cubed per minute).

The mass flow rate (measured in kilograms per second).

It is also possible to measure total flow which is the total volume or mass which has flowed in a set time period.

Fluid flow metering systems provide vital information for the following purpose :-

Production Planning ;- the quantities of product supplied to customers generally vary according to seasonal demand. Usually an average rate of production is planned on a calendar day which takes into account any periods of shutdown necessary for maintenance and inspection.

Product Quality ;- flow controllers are necessary in the proportional blending of intermediate products to produce on-specification finished products of consistent quality.

Control of Process ;- sometimes flow meters are used for control of some other main process variables. Examples in Separator column, liquid levels are kept constant by varying the flow rate of the process in columns are also kept constant by varying the flow rate of the process fluid passing through them. Pressure in column are also kept constant by varying the flow rate of the cooling medium .

What is Flow?

Flow is defined as fluid (liquids or/and gases) in motion.

Factors Affecting Flow Rates in pipes :

The major factors affecting the flow of fluids through pipes are:

the velocity of the fluid.

the friction of the fluid in contact with the pipe.

the viscosity of the fluid.

the density of the fluid.

Fluid velocity

Fluid velocity depends on the head pressure which is forcing the fluid through the pipe. The greater the head pressure, the faster the fluid flow rate (all other factors remaining constant), and consequently, the greater the volume of flow.

Pipe size also affects the flow rate. For example, doubling the diameter of a pipe increases the potential flow rate by a factor of four times.

Pipe friction

Pipe friction reduces the flow rate of fluids through pipes and is, therefore, considered a negative factor.

Because of the friction of a fluid in contact with a pipe, the flow rate of the fluid is slower near the walls of the pipe than at the center. The smoother, cleaner, and larger a pipe is, the less effect pipe friction has on the overall fluid flow rate.

Viscosity

Viscosity (η), or the molecular friction within a fluid, negatively affects the flow rate of fluids. Viscosity and pipe friction decrease the flow rate of a fluid near the walls of a pipe. Viscosity increases or decreases with changing temperature, but not always as might be expected. In liquids, viscosity typically decreases with increasing temperature.

However, in some fluids viscosity can begin to increase above certain temperatures. Generally, the higher a fluid’s viscosity, the lower the fluid flow rate (other factors remaining constant).

Viscosity is measured in units of centipoise. Another type of viscosity, called kinematic viscosity, is measured in units of centistokes. It is obtained by dividing centipoise by the fluid’s specific gravity.

Density

Density (ρ) of a fluid affects flow rates in that a more dense fluid requires more head pressure to maintain a desired flow rate. Also, the fact that gases are compressible, whereas liquids essentially are not, often requires that different methods be used for measuring the flow rates of liquids, gases, or liquids with gases in them.

It has been found that the most important flow factors can be correlated together into a dimensionless parameter called the Reynolds Number.

Understanding Flow

The Flow Law

If liquid flow through a pipe of varying diameters, at any particular time the same volume flows at all points. This means, the velocity of liquid must increase at a narrow point (see figure below).

Energy Balance in Flow
Back to the principle that energy is conserved within a system; it may just change from a state to another, the same principle applies to the flow within a flow closed-system. Consider the Below Diagram :
A liquid with a density of ρo flows constantly in a pipe with reducing diameters from A to B. Two points on the pipe were tapped with a small tube, namely Tapping 1 & Tapping 2, and results in two different levels of pressure.

The Law of Conservation of Energy, with respect to a flowing fluid, states that ‘the total energy of a flow of liquid does not change, as long as the system is kept closed (no external influences)’.

Neglecting the types of energy which do not change during flow, the total energy is made up of;

i. Potential Energy (due to position, and dependent on the height of head of liquid and on static pressure, equals to m·g·h).

ii. Kinetic Energy (due to movement, and dependent on the velocity of flow and on back pressure, equals to ½mv²)

If the velocity increases as the cross-section decreases, movement energy increases. As the total energy remains constant, potential energy and/or pressure must become smaller as the cross-section decreases.

There is no measurable change in potential energy. However, the static pressure changes, dependent upon the back pressure, i.e. dependent on the velocity of flow.

It is mainly the static pressure which is of importance in ‘hydro-static system’, as the height of head of liquid and velocity of flow are usually too small.











Comments

Popular posts from this blog

PLC Program for Mixing Tank

 Create a ladder diagram for controlling a batch mixing process. Implement a PLC program for mixing tank or Mixing Process using PLC Ladder Logic. PLC Program for Mixing Tank Fig : Mixing tank A tank is used to mix two liquids. The required control circuit operates as follows: A. When the START button is pressed, solenoids A and B energize. This permits the two liquids to begin filling the tank. B. When the tank is filled, the float switch trips. This de-energizes solenoids A and B and starts the motor used to mix the liquids together. C. The motor is permitted to run for 1 minute. After 1 minute has elapsed, the motor turns off and solenoid C energizes to drain the tank. D. When the tank is empty, the float switch de- energizes solenoid C. E. A STOP button can be used to stop the process at any point. F. If the motor becomes overloaded, the action of the entire circuit will stop. G. Once the circuit has been energized, it will continue to operate until it is manually stopped. Solution...

What is Relay? How it Works? Types, Applications, Testing

 We use relays for a wide range of applications such as home automation, cars and bikes (automobiles), industrial applications, DIY Projects, test and measurement equipment, and many more. But what is Relay? How a Relay Works? What are the Applications of Relays? Let us explore more about relays in this guide. What is a Relay? A Relay is a simple electromechanical switch. While we use normal switches to close or open a circuit manually, a Relay is also a switch that connects or disconnects two circuits. But instead of a manual operation, a relay uses an electrical signal to control an electromagnet, which in turn connects or disconnects another circuit. Relays can be of different types like electromechanical, solid state. Electromechanical relays are frequently used. Let us see the internal parts of this relay before knowing about it working. Although many different types of relay were present, their working is same. Every electromechanical relay consists of an consists of an Elect...

Chlorine dioxide Analyzer Principle

 Chlorine dioxide measurement Chlorine dioxide (ClO2) is an instable, non-storable, toxic gas with a characteristic scent. The molecule consists of one chlorine atom and two oxygen atoms – represented in the chemical formula ClO2. It is very reactive. To avoid the risk of spontaneous explosions of gaseous chlorine dioxide or concentrated solutions, it is generally handled in dilution with low concentrations. ClO2 is soluble in water, but tends to evaporate quickly. Typically it is prepared on site, for example from hydrochloric acid and sodium chlorite. The procedure provides solutions with approx. 2 g/l ClO2 that can be safely handled and stored for several days. Image Credits : krohne Sensor Parts : Reference electrode Applied chlorine dioxide specific potential Current needed to maintain the constant potential Counter electrode Measuring electrode The disinfection effect of ClO2 is due to the transfer of oxygen instead of chlorine, so that no chlorinated byproducts are formed. C...